Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Vertical ridge augmentation using a membrane technique associated with osseointegrated implants
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 14 , Issue 6
November/December 1994

Pages 497-512


Vertical ridge augmentation using a membrane technique associated with osseointegrated implants

Simion/Trisi/Piatteli


PMID: 7751115
DOI: 10.11607/prd.00.0110

The purpose of this study was to evaluate: (1) the surgical protocol, effectiveness, and reliability for vertical ridge augmentation using a new titanium-reinforced membrane and osseointegrated implants; and (2) the histologic characteristics of the interface between a pure titanium implant and newly regenerated human bone. Five patients received 15 conical Brånemark-type implants in six different surgical sites requiring vertical augmentation. The implants protruded 4 to 7 mm from the bone crest. Pure titanium miniscrews (1.3 x 10 mm) were positioned distally to the implants, protruding 3 to 4 mm from the bone level. The implants and the miniscrews were covered with a titanium-reinforced membrane, and the flaps were sutured. Membranes were removed at the stage 2 surgery after 9 months of healing. Measurements of biopsy specimens showed a gain in bone height from 3 to 4 mm. Histologic examination showed that all retrieved miniscrews were in direct contact with bone. Histomorphometric analysis of bone contact gave a mean value of 42.5 +/- 3.6% for five of the six examined miniscrews. The results suggest that the placement of implants protruding 3 to 4 mm from the top of resorbed bone surfaces may result in vertical bone regeneration to the top of the implant cylinder and that the regenerated bone is able to osseointegrate pure titanium implants.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help